69-year-old female patient

Revision, Treatment with MobileLink and MEGASYSTEM-C & Endo Model as intramedular total femur arthroplasty

Dr. Pablo Sanz-Ruiz

Department orthopedic surgery,
Gregorio Marañon hospital, Madrid, Spain

Case Description

Preoperative X-ray, June 2021

  • 1994: Primary THA right, secondary Perthes disease (other centre)
  • 2006: Acetabular revision due to polyethylene wear (other centre)
  • 2011: Femoral revision with a long stem (SROM) due to aseptic loosening (other centre)
  • 2013: Trochanteric fracture fix it with plate (other centre)
  • 06/2021: Introduction with..
    • Supracondylar femoral fracture after fall just in the tip of the long hip stem
    • Radiological loosening of the stem
    • Hip joint ankylosis (heterotopic calcification grade 3)

Course of Treatment

X-ray after surgery, June 2021

  • 06/2021: complete THA removal, defect classification acetabulum: IIC, defect classification femur: IIIA, Distal comminute supracondylar fracture
  • 06/2021: Reimplantation THA right with..
    • Extended trochanteric osteotomy was made to remove previous stem, due to bad bone quality, previous heterotopic calcification and to avoid trochanteric crack
    • Good bone cover was obtained with hemispheric cup using bone graft in the medial wall to restore the bone stock and center of rotation
    • Due to the limitation of the synthesis of femoral fracture and high risk of new fracture with to stem (hip and knee) we decide to do a intramedullary total femur arthroplasty with a endomodel tibial component , Mega C push through and endomodel femoral distal supplement
    • Dual Mobility Insert was used to decrease the dislocation risk
    • A new plate was used to close the ETO due to extremely bad bone quality
  • Components:
    • MobileLink TrabecuLink Multi Hole Shell, size 58; Dual Mobility Insert / size E, Bone Screws 6.5 / 50 mm x 2; 6.5 / 30 mm and 6.5 / 25 mm
    • Mega C push-through 14 x 240 mm
    • Endomodel M small, tibial stem 95 mm, and distal femoral replacement augment 50mm
    • MP short metaphysis XXL CCD 126º

Conclusion

Postoperative X-ray, 12-week follow-up

  • The modular MobileLink Acetabular Cup System allowed a good fixation, with the possibility of after fixation recon the COR. In this case, it was not necessary, however we can use a Dual Mobility Insert to decrease the risk of dislocation.
  • The result was excellent. The patients is walking without pain and she doesn´t need any assistance device to walk.
  • X-ray after 12 weeks:
    • Secure acetabular cup integrated and perfect function of intramedular total femur arthroplasty

Postoperative X-ray, 12-week follow-up

Dr. Pablo Sanz-Ruiz

Patient Case from
Madrid, Spain

  • 69-year-old female patient

  • Revision, Treatment with MobileLink, MEGASYSTEM-C & Endo Model

View Full Case

Dr. Steffen Brodt

Patient Case from
Eisenberg, Germany

  • 56-year-old male patient

  • Re-Revision, Treatment with MP Reconstruction System
     

View Full Case

 

Dr. Russell T. Nevins

Patient Case from
Las Vegas, USA

  • 69-year-old male patient

  • Re-Revision, Treatment with MP Reconstruction System
     

View Full Case

Dr. Rafael J. Sierra

Patient Case from
Minnesota, USA

  • 67-year-old female patient

  • Revision, Treatment with MP Reconstruction System
     

    View Full Case

Dr. Steffen Brodt

Patient Case from
Eisenberg, Germany

  • 79-year-old male patient

  • Re-Revision, Treatment with MP Reconstruction System, MobileLink, TrabecuLink Augment

View Full Case